Physical characteristics:

Main unit: Portable

Dimensions:L320xW205xH410

Weight:9.5kg

Technical specifications  

DEFIBRILLATOR

(1)Defibrillator type                     Manual, Synchronized, Asynchronized,

(2)Out put waveform                   Biphasic technology

(3)Energy accuracy                    ∠+1%

(4)Energy selection                    0, 3, 5, 7, 10, 20, 30, 50, 100, 200, 300, 360 joule (nominal ata resistance of 50)

(5)Charging time                        Maximum 8 seconds to 360 Joules

(6)Standard Adult/Pediatric Paddles   Reusable external adult paddles (pediatric paddles integrated)

Power requirements.

(a)AC Power supply                     110V, 60 Hz /220V, 50 Hz

(b)Vehicle Voltage                       DC 12V

Internal Battery Backup

(1)Battery type                  Rechargeable lead-acid battery

(2)Charging time               Time-Minimum of 4 hours for full charging

(3)Battery charging           During AC Power Supply operation of the device.

(4)Charging /Low Battery Indication      Red LED

(5)Battery Capacity           100% of the battery will provide 120 mins of monitoring; and 30 discharges at 360 joules.

Display

-LED Dimensions    7’diagonal {155mm*88mm} which is easily read from a distance.

-Type                      High resolution true-color graphic LED

-Resolution             480X234

– Provide cardioversion facilities with waveform annotated on the screen

– Display 4 seconds of ECG at 25mm/sec, ECG selectable from leads I, II, III when used with a 3-lead cable, and I, II, III aVL, aVR, aVF and V when used with a 5-lead cable.

– Display prompts, waveform settings, battery status, event summary and fault codes. Energy select is displayed by push button under the screen.

ECG

ECG lead: Ⅰ, Ⅱ, Ⅲ, AVR, AVL, AVF, V1~V6, GND

S-T segment analysis: -2.0~2.0mv

Arrhythmia analysis: yes

Protection: With stand 4000vAc/50Hz voltage in isolation and work against electrosurgical knife and defibrillation

Respiration

Measurement method: Thoracic impedance

Standard parameter & configuration

ECG/ RESP/DEFIBRILLATOR

-Provide audible and visual alarms for heart rate violations, VF and VT.

-Provide a strip printer which annotates waveforms, events, time code

-Have a 5-lead patient cable as an option to a 3-lead cable.

-Supplied with external re-usable paddles and packs of paper rolls for the printer.